RM-FTT Series Fixed Thermal Mass Flowmeter

Thermal mass flow meters are designed to measure the mass flow of gases. While standard flow meters require pressure and temperature compensation for accurate flow measurement, thermal mass flow meters can directly calculate the mass flow rate of the fluid without the need for such compensation. Mass flow meters are preferred due to their ease of application, lack of moving parts, very low pressure drop, wide measurement range, high accuracy, and high reliability. Thermal mass flow meters are predominantly used in sectors such as petroleum derivatives, the chemical industry, the medical industry, thermal power plants, and environmental protection.

Category: FLOW
Stock Code: RM-FTTM
  • Features
  • Document

Features

Description

Measurement Range

0 - 60 m/s velocity (at 20°C Temperature and 1.0133 Mpa Pressure)

Temperature Range

Main Display: -40°C - +85°C / Sensor: -10°C - +350°C

Accuracy

0.5% of Reading

Maximum Probe Length

500 mm

Probe Mounting

Pipe Diameter / 2 ± 25 mm

Output

Flow and Temperature: 4-20 mA Analog Output, Output impedance (Vs-12) / 0.02 Ohm

Material

AISI 316 Stainless Steel

Alarm Output

Photo-isolator Output 50V / 150 mADC

Temperature Coefficient 0.05% / 10°C
Pressure Effect Negligible / None
Response Time 1 sec
Power Supply 24 VDC ± 10% or 220 VAC ± 10%
Working Pressure 1.6 Mpa (Pressure values above this limit must be notified during the production stage.)
Communication Interface RS232 or RS485 (Changeable via user interface.)
User Menu Flow Range, Alarm Values, Calibration parameters, Temperature Range are adjustable.
Protection Class dIICT4 Ex-proof Protection (Except Acetylene)

 